Abaqus Volume II: I–Z Manual de usuario Pagina 291

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 628
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 290
*
POROUS FAILURE CRITERIA
16.19
*
POROUS FAILURE CRITERIA: Define porous material failure crit eria for a
*
POROUS
METAL PLASTICITY mo del.
This option is used to specify the material failure criteria in a porous metal.
Product: ABAQUS/Explicit
Type: Model data
Level: Model
References:
*
POROUS METAL PLASTICITY
“Porous metal plasticity,” Section 18.2.9 of the ABAQUS Analysis User ’s Manual
There are no parameters associated with this option.
Data line to define material failure criteria:
First (and only) line:
1. Void volume fracti on at total failure, . The default is 1.
2. Critical void volume fraction (threshold o f rapid loss of stress carrying capacity),
.The
default is
.
16.19–1