USER OUTPUT VARIABLES
20.7
*
USER OUTPUT VARIABLES: Specify number of user variables.
This option is used to allow ABAQ US to allocate space at each material calculation point for user-defined
output variables defined in user subroutine UVARM.Ifthe
*
USER OUTPUT VARIABLES option is used, it
must appear within each of the relevant material or gasket behavior definitions.
Product: ABAQUS/Standard
Type: Model data
Level: Model
Reference:
“UVARM,” Section 1.1.44 of the ABAQUS User Subroutines Reference Manual
There are no parameters associated with this option.
Data line to specify the number of user variables:
First (and only) line:
1. Number of user-defined variables required at each m aterial point.
20.7–1